Purpose
The procedure prints out the process control test pattern in two different modes. The comparison between the two prints can help isolate process control related image quality problems. Ensure that paper is loaded in tray 1 before starting this procedure as test patterns are printed.
The Procon On/Off Print consists of the following:
• Procon On Print: This is a print mode that uses the current Procon Data with the Procon (Process Control) soft enabled and the TRC Adjustment turned on.
• Procon Off Print: This is a print mode that uses IOT features with the Procon routine fully turned off.
Procedure
Procon On Print
1. Enter Diagnostics, GP 1.
2. Touch dC940 Procon On/Off Print.
3. Touch Procon On Print.
4. Touch Start. The internal test pattern Pcon PG is printed.
5. Check the image quality of the internal test pattern Pcon PG print.
6. Touch Close to return to the Procon On / Off Print screen.
Procon Off Print
1. Touch Procon Off Print.
2. Touch Start. The internal test pattern Pcon PG is printed.
3. Compare the output of the ProCon On and ProCon Off prints. Evaluate according to one of the following problem statements:
• The problem involves a single color, this is an indication that the imaging unit and/or power supplies or LPH may be at fault.
• The problem involves all colors, this is an indication that the 2nd BTR and/or transfer belt assembly may be at fault.
• The ProCon Off print is OK, but ProCon On print is unacceptable, this is an indication that process control items, rather than IOT items are at fault.
4. Touch Close to return to the Procon On / Off Print screen.
5. Touch Back to return to the Diagnostics screen.
6. Exit diagnostics, GP 1.
**This procedure is from Xerox Service Manual. All brand names and trademarks are their respective owner's property.**
You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.
Toner Chip (For North America and West Europe Region):
• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738
Toner Chip (For South America and East Europe Region):
• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766
Toner Chip (For Metered Machine):
• 106R03733 106R03736 106R03735 106R03734
Drum Chip:
• 113R00780 113R00782
The procedure prints out the process control test pattern in two different modes. The comparison between the two prints can help isolate process control related image quality problems. Ensure that paper is loaded in tray 1 before starting this procedure as test patterns are printed.
The Procon On/Off Print consists of the following:
• Procon On Print: This is a print mode that uses the current Procon Data with the Procon (Process Control) soft enabled and the TRC Adjustment turned on.
• Procon Off Print: This is a print mode that uses IOT features with the Procon routine fully turned off.
Procedure
Procon On Print
1. Enter Diagnostics, GP 1.
2. Touch dC940 Procon On/Off Print.
3. Touch Procon On Print.
4. Touch Start. The internal test pattern Pcon PG is printed.
5. Check the image quality of the internal test pattern Pcon PG print.
6. Touch Close to return to the Procon On / Off Print screen.
Procon Off Print
1. Touch Procon Off Print.
2. Touch Start. The internal test pattern Pcon PG is printed.
3. Compare the output of the ProCon On and ProCon Off prints. Evaluate according to one of the following problem statements:
• The problem involves a single color, this is an indication that the imaging unit and/or power supplies or LPH may be at fault.
• The problem involves all colors, this is an indication that the 2nd BTR and/or transfer belt assembly may be at fault.
• The ProCon Off print is OK, but ProCon On print is unacceptable, this is an indication that process control items, rather than IOT items are at fault.
4. Touch Close to return to the Procon On / Off Print screen.
5. Touch Back to return to the Diagnostics screen.
6. Exit diagnostics, GP 1.
**This procedure is from Xerox Service Manual. All brand names and trademarks are their respective owner's property.**
You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.
Toner Chip (For North America and West Europe Region):
• 106R03741 106R03744 106R03743 106R03742
• 106R03757 106R03760 106R03759 106R03758
• 106R03737 106R03740 106R03739 106R03738
Toner Chip (For South America and East Europe Region):
• 106R03749 106R03752 106R03751 106R03750
• 106R03745 106R03748 106R03747 106R03746
• 106R03765 106R03768 106R03767 106R03766
Toner Chip (For Metered Machine):
• 106R03733 106R03736 106R03735 106R03734
Drum Chip:
• 113R00780 113R00782