How to Fix 012-221B 012-223B Error Code for Xerox VersaLink C7020 C7025 C7030 C7000 Printer?

Posted by Xwk Tech on


012-221B, 012-223B Front Tamper Home Sensor Fail RAP

BSD-ON: BSD 13.3 Office Finisher LX Interlock Switching
BSD-ON: BSD 13.9 Office Finisher LX Tamping and Offset (1 of 2)
BSD-ON: BSD 13.10 Office Finisher LX Tamping and Offset (2 of 2)

Procedure

NOTE: Ensure the correct RAP is performed, refer to the 012-221, 012-223 Front Tamper Home Sensor Fail Entry RAP.

WARNING Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.

1. Manually operate the tamper mechanism. The tamper mechanism moves smoothly. If YES, go to 3. If No, go to 2.

2. Install a new components as necessary, PL 13.28.

3. Enter dC330 code 012-220 front tamper home sensor. Manually operate the tamper mechanism to actuate the front tamper home sensor. The display changes. If YES, go to 11. If No, go to 4.

4. Check the wiring between J8881 pin 2 and J8984 pin 5 for an open or short circuit, or a loose or damaged connector. The wiring is good. If YES, go to 6. If No, go to 5.

5. Reconnect or repair as necessary.

6. Measure the voltage between J8984 pins 6 and 4 on the finisher PWB. The voltage is approximately +5VDC. If YES, go to 8. If No, go to 7.

7. Install a new finisher PWB, PL 13.45 Item 2.

8. Measure the voltage between J8984 pin 5 on the finisher PWB and ground. Manually operate the tamper mechanism to actuate the front tamper home sensor. The voltage changes. If YES, go to 10. If No, go to 9.

9. Install a new front tamper home sensor, PL 13.28 Item 8.

10. Install a new finisher PWB, PL 13.45 Item 2.

11. Enter dC330 012-020 and 012-023 alternately. The front tamper motor runs. If YES, go to 19. If No, go to 12.

12. Measure the voltage between J8984 pin 19 on the finisher PWB and ground. The voltage is approximately +24VDC. If YES, go to 16. If No, go to 13.

13. Measure the voltage between J8982 pin 4 on the finisher PWB and ground. The voltage is approximately +24VDC. If YES, go to 15. If No, go to 14.

14. Check the +24VDC circuit. Refer to Chapter 7 Wiring Data. If the fault persists, install a new finisher PWB, PL 13.45 Item 2.

15. Install a new finisher PWB, PL 13.45 Item 2.

16. Check the wiring between J8984 pins 18 to 22 on the finisher PWB and the front tamper motor P/J8884 for an open or short circuit, or a loose or damaged connector. The wiring is good. If YES, go to 18. If No, go to 17

17. Reconnect or repair as necessary.

18. Install a new front tamper motor, PL 13.28 Item 6. If the fault persists, install a new finisher PWB, PL 13.45 Item 2.

19. Install a new finisher PWB, PL 13.45 Item 2.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner's property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

106R03741 106R03744 106R03743 106R03742
106R03757 106R03760 106R03759 106R03758
106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

106R03749 106R03752 106R03751 106R03750